apcupsd
У меня вопрос по subj - прописанно выполнение команды в PWRCMD, но при
пропадании питания она не выполняется :(
Используется Debian 2.2, конфиги прилагаются
--
Konstantin Kubatkin
KK4501-RIPE, Kherson, TriLogiC Group
Fido: 2:468/0@FidoNet
## apcupsd.conf v1.0 ##
#
# "apcupsd" POSIX config file
# Updated for Debian/GNU Linux by Leon Breedt (ljb@debian.org)
# CONTROL <string>
CONTROL /usr/sbin/powersc
# UPSCABLE [ simple | smart |
# 940-00(20B,23A,24B,24C,24G,95A,95C) |
# 940-15(24C) |
# ether ]
#
UPSCABLE 940-0024C
# UPSTYPE [ backups | sharebasic | netups |
# backupspro | smartvsups |
# newbackupspro | backupspropnp |
# smartups | matrixups | sharesmart ]
#
UPSTYPE smartups
# UPSCLASS [ standalone | shareslave | sharemaster | netslave | netmaster ]
UPSCLASS netmaster
# UPSMODE [ disable | share | net | sharenet ]
UPSMODE net
#DEVICE <string> /dev/<serial port>
DEVICE /dev/ttyS0
#LOCKFILE <path to lockfile>
LOCKFILE /var/lock
#ACCESS <string> [ true | false ] Enable Access Support
ACCESS true
# ANNOY <int> <30> <0> disables
ANNOY 30
# DELAY <int> <60> <0> disables
DELAY 60
# NOLOGON <string> [ disable | timeout | percent | minutes | always ]
NOLOGON timeout
# PROCFS <int> <120> <0> disables <update rate procfs-type of current status>
PROCFS 30
# LOGGING <int> <500> <0> disables <rate update log file of current status>
LOGGING 300
# TIMEOUT <time is seconds to run on UPS, powerfails>
# TIMEOUT 900
# BATTERYLEVEL <precent of battery charge for shutdown> 10
BATTERYLEVEL 10
# MINUTES <time in minutes of remainning battery charge before shutdown> 5
MINUTES 5
# SENSITIVITY <char> H,M,L default H
SENSITIVITY L
# WAKEUP <int> 0,60,180,300 Cycles default 0
WAKEUP 60
# SLEEP <int> 20,180,300,600 Cycles default 20
SLEEP 20
# LOTRANSFER <int> 0,1,2,3 default 2
LOTRANSFER 1
# HITRANSFER <int> 0,1,2,3 default 2
HITRANSFER 3
# RETURNCHARGE <int> 0,1,2,3 default 3
RETURNCHARGE 1
# BEEPSTATE <char> 0,T,L,N default 0
BEEPSTATE L
# SELFTEST <string> 336,168,ON,OFF default 336
SELFTEST 336
#
# UPSNAME <string>
UPSNAME Phuntic
# REPLACE <string> date format mm/dd/yy
#REPLACE 12/13/93
# BATTCMD <string>
BATTCMD /etc/ups/ups_bat_low
# TIMECMD <string>
#TIMECMD
# LOADCMD <string>
#LOADCMD
# LIMITCMD <string>
#LIMITCMD
# PWRCMD <string>
PWRCMD /etc/ups/ups_power_fail
# RETCMD <string>
RETCMD /etc/ups/ups_power_ret
# REMOTECMD <string>
#REMOTECMD
# NETTIME <int>
NETTIME 60
# NETPORT <int>
NETPORT 6666
# MASTER <string>
#MASTER
# SLAVE <string>
#SLAVE
#SLAVE
#SLAVE
#SLAVE
#SLAVE
#SLAVE
#SLAVE
#SLAVE
#SLAVE
#SLAVE
# USERMAGIC <string>
#USERMAGIC
# HTTPACCESS [ true | false ] enable web-interface - defaults to false
HTTPACCESS true
# HTTPPORT <port> port to use for interface - defaults to 1999
HTTPPORT 1999
APC : Oct 27 14:05:56
CABLE : APC Cable 940-0024C
UPSMODEL : SMART-UPS 2200
UPSMODE : Net Master
SHARE : NetworkUPS
UPSNAME : UPS_IDEN
ULINE : 214.5 Volts
MLINE : 222.3 Volts
NLINE : 213.2 Volts
FLINE : 49.2 Hz
VOUTP : 214.5 Volts
LOUTP : 059.2 Load Capacity
BOUTP : 55.0 Volts
BCHAR : 091.0 Batt. Charge
TIME : 17.0 Minutes
SENSE : LOW
WAKEUP : 060 Cycles
SLEEP : 020 Cycles
LOTRANS : 188.0 Volts
HITRANS : 280.0 Volts
CHARGE : 015.0 Percent
BFAIL : 0x08 Status Flag
UTEMP : 38.7 C Internal
ALARM : Low Batt
LASTEVNT : LINE VOLTAGE DECREASE
LOWBATT : 02 Minutes
DIPSW : 0x0000
Reply to: