Bug#829614: plasma-workspace: krunner no longer launches application
On Wed, 06 Jul 2016 12:51:59 +0200 Diederik de Haas <didi.debian@cknow.org>
wrote:
> On maandag 4 juli 2016 20:03:54 CEST Gard Spreemann wrote:
> > After upgrading plasma-workspace from 4:5.6.4-2 to 4:5.6.5.1-1 today,
> > krunner has stopped functioning correctly.
> >
> > -- System Information:
> > Debian Release: stretch/sid
> > APT prefers testing
> > APT policy: (990, 'testing'), (500, 'unstable')
>
> I see that various packages are at version 5.22.x while others are
> at 5.23.x. What happens if you upgrade those packages to the 5.23.x
> version, available in sid/unstable?
Hi all, and apologies for being slow to reply (I incorrectly
remembered having subscribed to the bug without actually having done
so).
After upgrading (only) libkf5plasma55.22.0-1 to 5.23.0-1, I am no
longer experiencing this bug.
Do I mark it as fixed in 5.23.0, or do we instead consider this a
non-bug I experienced because I had inadvertendly mixed Plasma
versions?
Best,
Gard